The plate heat exchanger at CDU, with tar at the hot side and crude oil at the cold side. The volume is 0.6 m3 each side. Deposits at both sides are products of thermal destruction of crude oil and tar, crude oil coke and pyrocoke. Deposit thickness is 2 mm.
temperature difference changed at hot side
temperature difference changed at cool side
additionally saved fuel per one fouled heat exchanger